ELCO BURNERS VGL 06.1600 DP s80-DN80 KL
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-080 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KL - cap lung |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP s2"-Rp 2" KM
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 20-5011 |
| Operation type | 2 trepte progresiv |
| Combustion head | KM - cap mediu |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s80-DN80 KM
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-080 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KM - cap mediu |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP d1"1/2-Rp2" KN
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 50 / 37 |
| Valve | Dungs MB-VEF 420 |
| Operation type | 2 trepte progresiv |
| Combustion head | KN - cap scurt |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s65-DN65 KN
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-065 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KN - cap scurt |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP d1"1/2-Rp2" KL
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 50 / 37 |
| Valve | Dungs MB-VEF 420 |
| Operation type | 2 trepte progresiv |
| Combustion head | KL - cap lung |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s65-DN65 KL
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-065 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KL - cap lung |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP d1"1/2-Rp2" KM
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 50 / 37 |
| Valve | Dungs MB-VEF 420 |
| Operation type | 2 trepte progresiv |
| Combustion head | KM - cap mediu |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s65-DN65 KM
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-065 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KM - cap mediu |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP d1"1/4-Rp2" KN
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 100 |
| Valve | Dungs MB-VEF 412 |
| Operation type | 2 trepte progresiv |
| Combustion head | KN - cap scurt |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s2"-Rp2" KN
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 50 |
| Valve | Siemens VGD 20 - 5011 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KN - cap scurt |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP d1"1/4-Rp2" KL
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 100 |
| Valve | Dungs MB-VEF 412 |
| Operation type | 2 trepte progresiv |
| Combustion head | KL - cap lung |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s2"-Rp2" KL
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 50 |
| Valve | Siemens VGD 20 - 5011 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KL - cap lung |
| Platform | Satronic |
..
ELCO BURNERS VG 5.1200 DP d1"1/4-Rp2" KM
| Model | VG 5.1200 |
| Burner minimal power [kW] | 250 |
| Burner max. power [kW] | 1160 |
| Gas pressure [mbar] | 100 |
| Valve | Dungs MB-VEF 412 |
| Operation type | 2 trepte progresiv |
| Combustion head | KM - cap mediu |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP s2"-Rp2" KM
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 50 |
| Valve | Siemens VGD 20 - 5011 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KM - cap mediu |
| Platform | Satronic |
..
ELCO BURNERS VG 6.1600 DP s65-DN65 TC KN
| Model | VG 6.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-065 |
| Operation type | 2 trepte progresiv |
| Combustion head | KN - cap scurt |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP d1"1/2-Rp2" KN
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 50 - 100 / 37 |
| Valve | Dungs MB-VEF 420 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KN - cap scurt |
| Platform | Satronic |
..
ELCO BURNERS VG 6.1600 DP s65-DN65 TC KL
| Model | VG 6.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-065 |
| Operation type | 2 trepte progresiv |
| Combustion head | KL - cap lung |
| Platform | Thermowatt |
..
ELCO BURNERS VGL 06.1600 DP d1"1/2-Rp2" KN
| Model | VGL 06.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 50 - 100 / 37 |
| Valve | Dungs MB-VEF 420 |
| Operation type | 2 trepte progresive gaz / 3 trepte motorina |
| Combustion head | KL - cap lung |
| Platform | Satronic |
..
ELCO BURNERS VG 6.1600 DP s65-DN65 TC KM
| Model | VG 6.1600 |
| Burner minimal power [kW] | 300 |
| Burner max. power [kW] | 1600 |
| Gas pressure [mbar] | 20 |
| Valve | Siemens VGD 40-065 |
| Operation type | 2 trepte progresiv |
| Combustion head | KM - cap mediu |
| Platform | Thermowatt |
..